Malays. J. Anal. Sci. Volume 30 Number 5 (2026): 1899
Research Article
Transient isotachophoresis-capillary zone electrophoresis
with capacitively coupled contactless conductivity detection for the analysis
of essential amino acids in complex feed matrices
Nurul
Natasha Yusoff1, Nur ‘Afifah Md Yusoff 1, Amirah
Farhan Kamaruddin1, Khairil Juhanni Abd Karim1,
Noorfatimah Yahaya2, Mohd Razif Mamat3, Yantus A.B.
Neolaka4, and Aemi Syazwani Abdul Keyon1,5*
1Department
of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM,
Johor Bahru, Johor, Malaysia
2Department of Toxicology, Advanced Medical and Dental Institute (AMDI),
Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Penang, Malaysia
3Synthetic Biology and Genetic Engineering Division Malaysia Genome &
Vaccine Institute (MGVI), Jalan Bangi, National Institute of Biotechnology
Malaysia (NIBM), Ministry of Science Technology and Innovation (MOSTI), 43000
Kajang, Selangor, Malaysia
4Department of Chemical Education, Faculty of Education and Teachers
Training, University of Nusa Cendana, Kupang 85001, Nusa Tenggara Timur,
Indonesia
5Centre
for Sustainable Nanomaterials (CSNano), Ibnu Sina Institute for Scientific and
Industrial Research, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru
Johor, Malaysia
*Corresponding author: aemi@utm.my
Received: 13 April 2026; Revised: 7 August 2026; Accepted: 9
August 2026; Published: 31 October 2026
Abstract
This
study presents an innovative CE[H1]
method that is combined with capacitively coupled contactless conductivity
detection to analyse essential amino acids in animal feed. Conventional
chromatographic methods for essential amino acids determination often involve
time-consuming derivatization and complex
procedures. Here, a transient isotachophoresis strategy is integrated into
CE-capacitively coupled contactless conductivity detection to enhance analyte
concentration and reduce matrix effects. Sodium ions were employed as the
leading ion, while the slowest migrating essential amino acids, i.e., tryptophan (Trp), served as the pseudo-terminating ion.
Acetic acid (pH 2.01) was used as the background electrolyte. Under optimized
conditions, nine essential amino acids were adequately separated (resolution
> 1.5) within 20 mins. The limits of detection ranged from 2.56 to 25.68 µM,
representing a 19- to 25-fold improvement, as compared to conventional
capillary zone electrophoresis. Intra-
and inter-day precision (relative standard deviation, n = 3) for migration time
and peak height were 0.28–6.20% and 0.51–8.55%, respectively, indicating good
repeatability and reproducibility. Method accuracy was assessed via spike
recovery experiments (5–15 µg/mL) in Trichanthera gigantea and Pennisetum
purpureum feed samples, yielding recoveries between 80.67% and 116.5%. The
developed method offers a rapid, sensitive, and minimal-solvent platform for
essential amino acids screening in complex feed matrices. Its applicability to
real samples and good analytical performance supports its potential for use in
agricultural research, feed quality control, and regulatory compliance. This method
promotes greener analytical workflows and provides a valuable tool for
advancing sustainable livestock nutrition practices.
Keywords: amino acid, animal feed, capillary electrophoresis,
online preconcentration, transient isotachophoresis
References
1.
Molina-Poveda, C. (2016). Aquafeed formulation (pp.
75–216). Elsevier.
2.
Li, P., & Wu, G. (2020). Composition of amino
acids and related nitrogenous nutrients in feedstuffs for animal diets. Amino
Acids, 52(4), 523–542.
3.
Wu, G. (2021). Amino acids: Biochemistry and
nutrition. CRC Press.
4.
Macelline, S. P., Wickramasuriya, S. S., Cho, H. M.,
Kim, E., Shin, T. K., Hong, J. S., Kim, J. C., Pluske, J. R., Choi, H. J.,
& Hong, Y. G. (2020). Broilers fed a low protein diet supplemented with
synthetic amino acids maintained growth performance and retained intestinal
integrity while reducing nitrogen excretion when raised under poor sanitary
conditions. Poultry Science, 99(2), 949–958.
5.
Commission of the European Communities. (1998).
Commission Directive 98/64/EC of 3 September 1998 establishing Community
methods of analysis for the determination of amino acids, crude oils and fats,
and olaquindox in feedingstuffs, and amending Directive 71/393/EEC. Official
Journal of the European Communities.
6.
Latimer, G. (Ed.). (2023). Official methods of
analysis of AOAC International. Oxford University Press.
7.
Macdonald, J. L., Krueger, M. W., & Keller, J. H.
(1985). Oxidation and hydrolysis determination of sulfur amino acids in food
and feed ingredients: Collaborative study. Journal of the Association of
Official Analytical Chemists, 68(5), 826–829.
8.
Allred, M. C., & Macdonald, J. L. (1988).
Determination of sulfur amino acids and tryptophan in foods and food and feed
ingredients: Collaborative study. Journal of the Association of Official
Analytical Chemists, 71(3), 603–606.
9.
International Organization for Standardization.
(2005). Animal feeding stuffs: Determination of amino acids content.
10. Wang, J.,
Niu, Y., Zhang, C., & Chen, Y. (2018). A micro-plate colorimetric assay for
rapid determination of trace zinc in animal feed, pet food and drinking water
by ion masking and statistical partitioning correction. Food Chemistry, 245,
337–345.
11. Danielsen,
M., Nebel, C., & Dalsgaard, T. K. (2020). Simultaneous determination of L-
and D-amino acids in proteins: A sensitive method using hydrolysis in
deuterated acid and liquid chromatography–tandem mass spectrometry analysis. Foods,
9(3), 309.
12. Weber, P.
(2022). Determination of amino acids in food and feed by microwave hydrolysis
and UHPLC-MS/MS. Journal of Chromatography B, 1209: 123429.
13. Latorre, R.
M., Saurina, J., & Hernández-Cassou, S. (2001). Sensitivity enhancement by
on-line preconcentration and in-capillary derivatization for the
electrophoretic determination of amino acids. Electrophoresis, 22(20),
4355–4361.
14. Komarova,
N., Kamentsev, J., Solomonova, A., & Anufrieva, R. (2004). Determination of
amino acids in fodders and raw materials using capillary zone electrophoresis. Journal
of Chromatography B, 800(1–2), 135–143.
15. Hauser, P.
C., & Kubáň, P. (2025). Contactless conductivity detection for
capillary electrophoresis—Developments from 2020 to 2024. Electrophoresis, 46(13–14),
829–862.
16. Ta, H. Y.,
Collin, F., Perquis, L., Poinsot, V., Ong-Meang, V., & Couderc, F. (2021).
Twenty years of amino acid determination using capillary electrophoresis: A
review. Analytica Chimica Acta, 1174: 338233.
17. Tůma,
P. (2021). Determination of amino acids by capillary and microchip
electrophoresis with contactless conductivity detection—Theory, instrumentation
and applications. Talanta, 224: 121922.
18. Kartsova,
L., & Maliushevska, A. (2024). Determination of amino acids and peptides
without their pre-column derivatization by capillary electrophoresis with
ultraviolet and contactless conductivity detection: An overview. Journal of
Separation Science, 47(16): 2400352.
19. Hodek, O.,
Křížek, T., Coufal, P., & Ryšlavá, H. (2017). Design of experiments
for amino acid extraction from tobacco leaves and their subsequent
determination by capillary zone electrophoresis. Analytical and
Bioanalytical Chemistry, 409(9), 2383–2391.
20. Malá, Z.,
& Gebauer, P. (2022). Recent progress in analytical capillary
isotachophoresis (2018–March 2022). Journal of Chromatography A, 1677: 463337.
21. MTC USA.
(n.d.). FAQ: Capillary electrophoresis CE100SA-TI. Access from https://www.mtc-usa.com/faqce100sa_ti
22. Wei, R.,
Li, W., Yang, L., Jiang, Y., & Xie, T. (2011). Online preconcentration in
capillary electrophoresis with contactless conductivity detection for sensitive
determination of sorbic and benzoic acids in soy sauce. Talanta, 83(5),
1487–1490.
23. Duong, H.
A., Vu, M. T., Nguyen, T. D., Nguyen, M. H., & Mai, T. D. (2020).
Determination of 10-hydroxy-2-decenoic acid and free amino acids in royal jelly
supplements with purpose-made capillary electrophoresis coupled with
contactless conductivity detection. Journal of Food Composition and
Analysis, 87: 103422.
24. Tůma,
P., Málková, K., Samcová, E., & Štulík, K. (2010). Rapid monitoring of
arrays of amino acids in clinical samples using capillary electrophoresis with
contactless conductivity detection. Journal of Separation Science, 33(16),
2394–2401.
25. Shihabi, Z.
K. (2002). Transient pseudo-isotachophoresis for sample concentration in
capillary electrophoresis. Electrophoresis, 23(11), 1612–1617.
26. Primer, A.
(2009). High performance capillary electrophoresis. [Publisher details to be
verified].
27. U.S. Food
and Drug Administration. (2021). Q2(R1) validation of analytical procedures:
Text and methodology guidance for industry: Final guidance for industry.
28. Wang, M.,
Guo, J., Lin, H., Zou, D., Zhu, J., Yang, Z., Huang, Y., & He, F. (2024).
UHPLC-QQQ-MS/MS method for the simultaneous quantification of 18 amino acids in
various meats. Frontiers in Nutrition, 11: 1467149.
29. Zhao, R.,
Huang, B., Lu, G., Fu, S., Ying, J., & Zhao, Y. (2023). A practical method
for amino acid analysis by LC-MS using precolumn derivatization with urea. International
Journal of Molecular Sciences, 24(8), 7332.
[H1]Please put full term (CE). After that can use CE, sebab first stated in manuscript, harus full term..selepas itu, boleh gunakan short form