Malays. J. Anal. Sci. Volume 30 Number 5 (2026): 1899

 

Research Article

 

Transient isotachophoresis-capillary zone electrophoresis with capacitively coupled contactless conductivity detection for the analysis of essential amino acids in complex feed matrices

 

Nurul Natasha Yusoff1, Nur ‘Afifah Md Yusoff 1, Amirah Farhan Kamaruddin1, Khairil Juhanni Abd Karim1, Noorfatimah Yahaya2, Mohd Razif Mamat3, Yantus A.B. Neolaka4, and Aemi Syazwani Abdul Keyon1,5*

 

1Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru, Johor, Malaysia

2Department of Toxicology, Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia, Bertam, 13200 Kepala Batas, Penang, Malaysia

3Synthetic Biology and Genetic Engineering Division Malaysia Genome & Vaccine Institute (MGVI), Jalan Bangi, National Institute of Biotechnology Malaysia (NIBM), Ministry of Science Technology and Innovation (MOSTI), 43000 Kajang, Selangor, Malaysia

4Department of Chemical Education, Faculty of Education and Teachers Training, University of Nusa Cendana, Kupang 85001, Nusa Tenggara Timur, Indonesia

5Centre for Sustainable Nanomaterials (CSNano), Ibnu Sina Institute for Scientific and Industrial Research, Universiti Teknologi Malaysia, 81310 UTM, Johor Bahru Johor, Malaysia

 

*Corresponding author: aemi@utm.my

 

Received: 13 April 2026; Revised: 7 August 2026; Accepted: 9 August 2026; Published: 31 October 2026

 

Abstract

This study presents an innovative CE[H1]  method that is combined with capacitively coupled contactless conductivity detection to analyse essential amino acids in animal feed. Conventional chromatographic methods for essential amino acids determination often involve time-consuming derivatization and     complex procedures. Here, a transient isotachophoresis strategy is integrated into CE-capacitively coupled contactless conductivity detection to enhance analyte concentration and reduce matrix effects. Sodium ions were employed as the leading ion, while the slowest migrating essential amino acids, i.e., tryptophan (Trp), served as the pseudo-terminating ion. Acetic acid (pH 2.01) was used as the background electrolyte. Under optimized conditions, nine essential amino acids were adequately separated (resolution > 1.5) within 20 mins. The limits of detection ranged from 2.56 to 25.68 µM, representing a 19- to 25-fold improvement, as compared to conventional capillary    zone electrophoresis. Intra- and inter-day precision (relative standard deviation, n = 3) for migration time and peak height were 0.28–6.20% and 0.51–8.55%, respectively, indicating good repeatability and reproducibility. Method         accuracy was assessed via spike recovery experiments (5–15 µg/mL) in Trichanthera gigantea and Pennisetum purpureum feed samples, yielding recoveries between 80.67% and 116.5%. The developed method offers a rapid, sensitive, and minimal-solvent platform for essential amino acids screening in complex feed matrices. Its applicability to real samples and good analytical performance supports its potential for use in agricultural research, feed quality control, and regulatory compliance. This method promotes greener analytical workflows and provides a valuable tool for advancing sustainable livestock nutrition practices.

 

Keywords: amino acid, animal feed, capillary electrophoresis, online preconcentration, transient isotachophoresis

 


References

1.        Molina-Poveda, C. (2016). Aquafeed formulation (pp. 75–216). Elsevier.

2.        Li, P., & Wu, G. (2020). Composition of amino acids and related nitrogenous nutrients in feedstuffs for animal diets. Amino Acids, 52(4), 523–542.

3.        Wu, G. (2021). Amino acids: Biochemistry and nutrition. CRC Press.

4.        Macelline, S. P., Wickramasuriya, S. S., Cho, H. M., Kim, E., Shin, T. K., Hong, J. S., Kim, J. C., Pluske, J. R., Choi, H. J., & Hong, Y. G. (2020). Broilers fed a low protein diet supplemented with synthetic amino acids maintained growth performance and retained intestinal integrity while reducing nitrogen excretion when raised under poor sanitary conditions. Poultry Science, 99(2), 949–958.

5.        Commission of the European Communities. (1998). Commission Directive 98/64/EC of 3 September 1998 establishing Community methods of analysis for the determination of amino acids, crude oils and fats, and olaquindox in feedingstuffs, and amending Directive 71/393/EEC. Official Journal of the European Communities.

6.        Latimer, G. (Ed.). (2023). Official methods of analysis of AOAC International. Oxford University Press.

7.        Macdonald, J. L., Krueger, M. W., & Keller, J. H. (1985). Oxidation and hydrolysis determination of sulfur amino acids in food and feed ingredients: Collaborative study. Journal of the Association of Official Analytical Chemists, 68(5), 826–829.

8.        Allred, M. C., & Macdonald, J. L. (1988). Determination of sulfur amino acids and tryptophan in foods and food and feed ingredients: Collaborative study. Journal of the Association of Official Analytical Chemists, 71(3), 603–606.

9.        International Organization for Standardization. (2005). Animal feeding stuffs: Determination of amino acids content.

10.     Wang, J., Niu, Y., Zhang, C., & Chen, Y. (2018). A micro-plate colorimetric assay for rapid determination of trace zinc in animal feed, pet food and drinking water by ion masking and statistical partitioning correction. Food Chemistry, 245, 337–345.

11.     Danielsen, M., Nebel, C., & Dalsgaard, T. K. (2020). Simultaneous determination of L- and D-amino acids in proteins: A sensitive method using hydrolysis in deuterated acid and liquid chromatography–tandem mass spectrometry analysis. Foods, 9(3), 309.

12.     Weber, P. (2022). Determination of amino acids in food and feed by microwave hydrolysis and UHPLC-MS/MS. Journal of Chromatography B, 1209: 123429.

13.     Latorre, R. M., Saurina, J., & Hernández-Cassou, S. (2001). Sensitivity enhancement by on-line preconcentration and in-capillary derivatization for the electrophoretic determination of amino acids. Electrophoresis, 22(20), 4355–4361.

14.     Komarova, N., Kamentsev, J., Solomonova, A., & Anufrieva, R. (2004). Determination of amino acids in fodders and raw materials using capillary zone electrophoresis. Journal of Chromatography B, 800(1–2), 135–143.

15.     Hauser, P. C., & Kubáň, P. (2025). Contactless conductivity detection for capillary electrophoresis—Developments from 2020 to 2024. Electrophoresis, 46(13–14), 829–862.

16.     Ta, H. Y., Collin, F., Perquis, L., Poinsot, V., Ong-Meang, V., & Couderc, F. (2021). Twenty years of amino acid determination using capillary electrophoresis: A review. Analytica Chimica Acta, 1174: 338233.

17.     Tůma, P. (2021). Determination of amino acids by capillary and microchip electrophoresis with contactless conductivity detection—Theory, instrumentation and applications. Talanta, 224: 121922.

18.     Kartsova, L., & Maliushevska, A. (2024). Determination of amino acids and peptides without their pre-column derivatization by capillary electrophoresis with ultraviolet and contactless conductivity detection: An overview. Journal of Separation Science, 47(16): 2400352.

19.     Hodek, O., Křížek, T., Coufal, P., & Ryšlavá, H. (2017). Design of experiments for amino acid extraction from tobacco leaves and their subsequent determination by capillary zone electrophoresis. Analytical and Bioanalytical Chemistry, 409(9), 2383–2391.

20.     Malá, Z., & Gebauer, P. (2022). Recent progress in analytical capillary isotachophoresis (2018–March 2022). Journal of Chromatography A, 1677: 463337.

21.     MTC USA. (n.d.). FAQ: Capillary electrophoresis CE100SA-TI. Access from https://www.mtc-usa.com/faqce100sa_ti

22.     Wei, R., Li, W., Yang, L., Jiang, Y., & Xie, T. (2011). Online preconcentration in capillary electrophoresis with contactless conductivity detection for sensitive determination of sorbic and benzoic acids in soy sauce. Talanta, 83(5), 1487–1490.

23.     Duong, H. A., Vu, M. T., Nguyen, T. D., Nguyen, M. H., & Mai, T. D. (2020). Determination of 10-hydroxy-2-decenoic acid and free amino acids in royal jelly supplements with purpose-made capillary electrophoresis coupled with contactless conductivity detection. Journal of Food Composition and Analysis, 87: 103422.

24.     Tůma, P., Málková, K., Samcová, E., & Štulík, K. (2010). Rapid monitoring of arrays of amino acids in clinical samples using capillary electrophoresis with contactless conductivity detection. Journal of Separation Science, 33(16), 2394–2401.

25.     Shihabi, Z. K. (2002). Transient pseudo-isotachophoresis for sample concentration in capillary electrophoresis. Electrophoresis, 23(11), 1612–1617.

26.     Primer, A. (2009). High performance capillary electrophoresis. [Publisher details to be verified].

27.     U.S. Food and Drug Administration. (2021). Q2(R1) validation of analytical procedures: Text and methodology guidance for industry: Final guidance for industry.

28.     Wang, M., Guo, J., Lin, H., Zou, D., Zhu, J., Yang, Z., Huang, Y., & He, F. (2024). UHPLC-QQQ-MS/MS method for the simultaneous quantification of 18 amino acids in various meats. Frontiers in Nutrition, 11: 1467149.

29.     Zhao, R., Huang, B., Lu, G., Fu, S., Ying, J., & Zhao, Y. (2023). A practical method for amino acid analysis by LC-MS using precolumn derivatization with urea. International Journal of Molecular Sciences, 24(8), 7332.

 

 


 [H1]Please put full term (CE). After that can use CE, sebab first stated in manuscript, harus full term..selepas itu, boleh gunakan short form