Malays. J. Anal. Sci. Volume 30 Number 5 (2026): 1887
Research Article
Response
surface methodology assisted electrochemical sensor for the detection of 3-MCPD
Mohd
Zaheer Khan Mohd Ali1, Wan Jefrey Basirun2, Zainiharyati
Mohd Zain3, Siti Nor Atika Baharin1, Mohd Azerulazree
Jamilan4, and Kavirajaa Pandian Sambasevam1,3*
1Advanced
Materials for Environmental Remediation (AMER), Faculty of Applied Sciences,
Universiti Teknologi MARA, Cawangan Negeri Sembilan, Kampus Kuala Pilah, 72000,
Kuala Pilah, Negeri Sembilan, Malaysia
2Department
of Chemistry, Faculty of Science, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
3Electrochemical
Material and Sensor (EMaS) Research Group, Universiti Teknologi MARA, Shah
Alam, 40450 Selangor Malaysia
4 Nutrition
Unit, Nutrition, Metabolism and Cardiovascular Research Centre (NMCRC), Institute
for Medical Research, National Institute of Health, Ministry of Health Malaysia,
No. 1, Jalan Setia Murni U13/52, Setia Alam, 40170 Shah Alam, Selangor D.E.,
Malaysia
*Corresponding author: kavirajaa@uitm.edu.my
Received: 1 April 2026; Revised: 12 June 2026;
Accepted: 24 June 2026; Published: 31 October 2026
Abstract
3-MCPD
(3-monochloropropane-1,2-diol) is a chemical contaminant formed during
high-heat food processing. It is mostly found in refined vegetable oils
(especially palm oil) and soy sauce. It is a suspected human carcinogen and has
been linked to kidney damage. Because of these severe health risks, global food
safety authorities strictly regulate and monitor its levels to ensure public
safety. A molecularly imprinted polypyrrole/chitosan (MIPPy/CHT)
electrochemical sensor was fabricated via electropolymerization for the
selective detection of 3-monochloropropane-1,2-diol (3-MCPD). The surface
morphology and elemental composition were characterized using field emission
scanning electron microscopy (FESEM) coupled with energy-dispersive X-ray
spectroscopy (EDX), while electrochemical techniques were employed to evaluate
interfacial behavior and sensing performance. Fabrication parameters were systematically
optimized using Response Surface Methodology (RSM). A two-level factorial
design identified pH, number of scans, starting potential, and elution time as
influential factors, with pronounced quadratic effects observed for pH, scan
number, and starting potential. Mildly acidic conditions (pH 4) enhanced
hydrogen-bonding interactions, while excessive number of scans and higher
starting potentials for sensor fabrication reduced sensor response(A).
Subsequent optimization using a Box–Behnken design (BBD) established optimal
conditions at pH 4, 3 electropolymerization scans, lower electropolymerization
starting potential at 0V, and 15 min elution time. Significant interaction
effects were observed between pH and scan number, as well as between scan
number and starting potential, confirming the critical balance between polymer
growth and cavity accessibility. Under optimized conditions, the sensor
exhibited a linear response toward 3-MCPD over 100–500 nM with a high
correlation coefficient (R˛ = 0.9963). The limit of detection (LOD) and limit
of quantification (LOQ) were 36 nM and 111 nM, respectively. These results
demonstrate that the MIPPy/CHT sensor provides high sensitivity, good
selectivity, and reliable analytical performance for 3-MCPD detection.
Keywords:
3-monochloropropane-1,2-diol, molecularly imprinted polymer, polypyrrole/chitosan
composite, electrochemical sensor, response surface methodology
References
1.
Sulin, S., Mokhtar, M., Mohammed, M., & Baharuddin,
A. (2020). Review on palm oil contaminants related to 3-monochloropropane-1,
2-diol (3-MCPD) and glycidyl esters (GE). Food
Research, 4(S6), 11-18.
2.
Buhrke, T., Schultrich, K., Braeuning, A., & Lampen,
A. (2017). Comparative analysis of transcriptomic responses to repeated-dose
exposure to 2-MCPD and 3-MCPD in rat kidney, liver and testis. Food and Chemical Toxicology, 106,
36-46.
3.
Eisenreich, A., Monien, B. H., Götz, M. E., Buhrke, T.,
Oberemm, A., Schultrich, K., Abraham, K., Braeuning, A., & Schäfer, B.
(2023). 3-MCPD as contaminant in processed foods: State of knowledge and
remaining challenges. Food Chemistry, 403,
134332.
4.
Chain, E. Panel o. C. i. t. F. (2016). Risks for
human health related to the presence of 3- and 2-monochloropropanediol (MCPD),
and their fatty acid esters, and glycidyl fatty acid esters in food. EFSA Journal, 14(5), e04426.
5.
Wong, K. O., Cheong, Y. H., & Seah, H. L. (2006).
3-Monochloropropane-1,2-diol (3-MCPD) in soy and oyster sauces: Occurrence and
dietary intake assessment. Food Control, 17(5),
408-413.
6.
Baer, I., De la Calle, B., & Taylor, P. (2010).
3-MCPD in food other than soy sauce or hydrolysed vegetable protein (HVP). Analytical and Bioanalytical Chemistry, 396(1),
443-456.
7.
Parisi, O. I., Francomano, F., Dattilo, M., Patitucci,
F., Prete, S., Amone, F., & Puoci, F. (2022). The Evolution of Molecular
Recognition: From Antibodies to Molecularly Imprinted Polymers (MIPs) as
Artificial Counterpart. Journal of
Functional Biomaterials, 13(1), 12. 2079-4983.
8.
Sun, X., Zhang, L., Zhang, H., Qian, H., Zhang, Y., Tang,
L., & Li, Z. (2014). Development and application of 3-chloro-1,2-propandiol
electrochemical sensor based on a polyaminothiophenol modified molecularly
imprinted film. Journal of Agricultural
and Food Chemistry, 62(20), 4552-4557.
9.
Martin, A. A., Fodjo, E. K., Eric-Simon, Z. V., Gu, Z.,
Yang, G., Albert, T., Kong, C., & Wang, H.-F. (2021). Cys-AgNPs modified
gold electrode as an ultrasensitive electrochemical sensor for the detection of
3-chloropropane-1,2-diol. Arabian Journal
of Chemistry, 14(9), 103319.
10.
Cheng, W., Zhang, Q., Wu, D., Yang, Y., Zhang, Y., &
Tang, X. (2022). A facile electrochemical method for rapid determination of
3-chloropropane-1,2-diol in soy sauce based on nanoporous gold capped with
molecularly imprinted polymer. Food
Control, 134, 108750.
11.
Chi, H., Li, Y., & Liu, G. (2022). Molecularly
imprinted sensing platform based on electrochemically modified graphite paper
for efficient detection of 3-monochloropropane-1,2-diol. Food Chemistry, 386, 132829.
12.
Yaman, Y. T., Bolat, G., Saygin, T. B., & Abaci, S.
(2021). Molecularly imprinted label-free sensor platform for impedimetric
detection of 3-monochloropropane-1,2˗diol. Sensors and Actuators B: Chemical, 328, 128986.
13.
Pang, A. L., Arsad, A., & Ahmadipour, M. (2021).
Synthesis and factor affecting on the conductivity of polypyrrole: a short
review. Polymers for Advanced
Technologies, 32(4), 1428-1454.
14.
Deng, F., Li, Y., Luo, X., Yang, L., & Tu, X. (2012).
Preparation of conductive polypyrrole/TiO2 nanocomposite via surface molecular
imprinting technique and its photocatalytic activity under simulated solar
light irradiation. Colloids and Surfaces
A: Physicochemical and Engineering Aspects, 395, 183-189.
15.
Xu, L., Huang, Y.-A., Zhu, Q.-J., & Ye, C. (2015).
Chitosan in Molecularly-Imprinted Polymers: Current and Future Prospects. International Journal of Molecular Sciences, 16(8),
18328-18347.
16.
Sambasevam, K. P., Sateria, S. F., Baharin, S. N. A.,
Azman, N. J., Ahmad Wakid, S., & Shahabuddin, S. (2023). An optimization of
fungal chitin grafted polyaniline for ammonia gas detection via Box Behnken
design. International Journal of
Biological Macromolecules, 238, 124079.
17.
Ferreira, S. L. C., Bruns, R. E., Ferreira, H. S., Matos,
G. D., David, J. M., Brandăo, G. C., da Silva, E. G. P., Portugal, L. A., dos
Reis, P. S., Souza, A. S., & dos Santos, W. N. L. (2007). Box-Behnken
design: An alternative for the optimization of analytical methods. Analytica Chimica Acta, 597(2), 179-186.
18.
Fang, M., Zhou, L., Zhang, H., Liu, L., & Gong, Z.-Y.
(2019). A molecularly imprinted polymers/carbon dots-grafted paper sensor for
3-monochloropropane-1,2-diol determination. Food
Chemistry, 274, 156-161.
19.
Xing, X., & Cao, Y. (2007). Determination of
3-chloro-1,2-propanediol in soy sauces by capillary electrophoresis with
electrochemical detection. Food Control, 18(2),
167-172.
20.
Geng, X., Kwon, O.-H., & Jang, J. (2005).
Electrospinning of chitosan dissolved in concentrated acetic acid solution. Biomaterials, 26(27), 5427-5432.
21.
Albar, M. M. J., Jamion, N. A., Baharin, S. N. A., Raoov,
M., & Sambasevam, K. P. (2020). Preparation of novel commercial polyaniline
composites for ammonia detection. Solid State Phenomena, 301, 124-131.
22.
Yang, Y., Fang, G., Wang, X., Pan, M., Qian, H., Liu, H.,
& Wang, S. (2014). Sensitive and selective electrochemical determination of
quinoxaline-2-carboxylic acid based on bilayer of novel poly(pyrrole)
functional composite using one-step electro-polymerization and molecularly
imprinted poly(o-phenylenediamine). Analytica
Chimica Acta, 806, 136-143.
23.
Bougrini, M., Florea, A., Cristea, C., Sandulescu, R.,
Vocanson, F., Errachid, A., Bouchikhi, B., El Bari, N., &
Jaffrezic-Renault, N. (2016). Development of a novel sensitive molecularly
imprinted polymer sensor based on electropolymerization of a microporous-metal-organic
framework for tetracycline detection in honey. Food Control, 59,
424-429.
24.
Pfaff, T. J. (2023). Formulas Quantifying Change. In T.
J. Pfaff (Ed.), Applied Calculus with R
(pp. 65-76). Springer International Publishing.
25.
Ahmed, R. K., Saad, E. M., Fahmy, H. M., & El Nashar,
R. M. (2022). Multivariate experimental design: towards more reliable
electrochemical detection. Current
Opinion in Electrochemistry, 31, 100880.
26.
Ling, T.-R., Hsieh, W.-C., Li, Y.-Y., & Hung, T.-T.
(2023). MIP sensor made using multi-current step electro-polymerization method
on framed Ag-SPE for glutamic acid enantiomer recognition. Journal of Electroanalytical Chemistry, 944, 117635.
27.
Zembrzuska, D., Kalecki, J., Cieplak, M., Lisowski, W.,
Borowicz, P., Noworyta, K., & Sharma, P. S. (2019). Electrochemically
initiated co-polymerization of monomers of different oxidation potentials for
molecular imprinting of electroactive analyte. Sensors and Actuators B: Chemical, 298, 126884.
28.
Wu, Y., Li, G., Tian, Y., Feng, J., Xiao, J., Liu, J.,
Liu, X., & He, Q. (2021). Electropolymerization of molecularly imprinted
polypyrrole film on multiwalled carbon nanotube surface for highly selective
and stable determination of carcinogenic amaranth. Journal of Electroanalytical Chemistry, 895, 115494.
29.
Di Masi, S., De Benedetto, G. E., & Malitesta, C.
(2024). Optimisation of electrochemical sensors based on molecularly imprinted
polymers: from OFAT to machine learning. Analytical
and Bioanalytical Chemistry, 416(9), 2261-2275.
30.
Szpisják-Gulyás, N., Al-Tayawi, A. N., Horváth, Z. H.,
László, Z., Kertész, S., & Hodúr, C. (2023). Methods for experimental
design, central composite design and the Box–Behnken design, to optimise
operational parameters: A review. Acta
Alimentaria, 52(4), 521-537.
31.
Martin, A. A., Fodjo, E. K., Marc, G. B. I., Albert, T.,
& Kong, C. (2021). Simple and rapid detection of free
3-monochloropropane-1,2-diol based on cysteine modified silver nanoparticles. Food Chemistry, 338, 127787.
32.
Alizadeh, T., Ganjali, M. R., Zare, M., & Norouzi, P.
(2010). Development of a voltammetric sensor based on a molecularly imprinted
polymer (MIP) for caffeine measurement. Electrochimica
Acta, 55(5), 1568-1574.
33.
da Silva, H., Pacheco, J., Silva, J., Viswanathan, S.,
& Delerue-Matos, C. (2015). Molecularly imprinted sensor for voltammetric
detection of norfloxacin. Sensors and
Actuators B: Chemical, 219, 301-307.
34.
Cheng, Z., Wang, E., & Yang, X. (2001). Capacitive
detection of glucose using molecularly imprinted polymers. Biosensors and Bioelectronics,
16(3), 179-185.
35.
Akpinar, H., Nurioglu, A. G., & Toppare, L. (2012).
Influence of hydrogen bonding on electrochromic properties of conducting
polymers. Journal of Electroanalytical
Chemistry, 683, 62-69.
36.
Yang, R., Ruan, C., Dai, W., Deng, J., & Kong, J.
(1999). Electropolymerization of thionine in neutral aqueous media and H2O2
biosensor based on poly(thionine). Electrochimica
Acta, 44(10), 1585-1596.
37.
Tamandani, M., & Hashemi, S. H. (2022). Central
Composite Design (CCD) and Box-Behnken Design (BBD) for the Optimization of a
Molecularly Imprinted Polymer (MIP) Based Pipette Tip Micro-Solid Phase
Extraction (SPE) for the Spectrophotometric Determination of Chlorpyrifos in
Food and Juice. Analytical Letters, 55(15),
2394-2408.
38.
Sulaiman, N. S., Hashim, R., Mohamad Amini, M. H.,
Danish, M., & Sulaiman, O. (2018). Optimization of activated carbon
preparation from cassava stem using response surface methodology on surface
area and yield. Journal of Cleaner
Production, 198, 1422-1430.
39.
Das, S., & Mishra, S. (2017). Box-Behnken statistical
design to optimize preparation of activated carbon from Limonia acidissima
shell with desirability approach. Journal
of Environmental Chemical Engineering,
5(1), 588-600.
40.
Natarajan, E., & Ponnaiah, G. P. (2017). Optimization
of process parameters for the decolorization of Reactive Blue 235 dye by barium
alginate immobilized iron nanoparticles synthesized from aluminum industry
waste. Environmental Nanotechnology,
Monitoring & Management, 7,
73-88.
41.
Ghoreishian, S. M., Raju, G. S. R., Pavitra, E., Kwak, C.
H., Han, Y.-K., & Huh, Y. S. (2019). Ultrasound-assisted heterogeneous
degradation of tetracycline over flower-like rGO/CdWO4 hierarchical structures
as robust solar-light-responsive photocatalysts: Optimization, kinetics, and
mechanism. Applied Surface Science, 489,
110-122.
42. Ozkorucuklu, S. P., Sahin, Y., &
Alsancak, G. (2008). Voltammetric behaviour of sulfamethoxazole on
electropolymerized-molecularly imprinted overoxidized polypyrrole. Sensors, 8(12), 8463-8478.
43. Zeb, S., Wong, A., Khan, S.,
Hussain, S., & Sotomayor, M. D. P. T. (2021). Using magnetic
nanoparticles/MIP-based electrochemical sensor for quantification of
tetracycline in milk samples. Journal of
Electroanalytical Chemistry, 900, 115713.
44. Naskar, H., Ghatak, B., Biswas, S.,
Singh, P. P., Tudu, B., & Bandyopadhyay, R. (2020). Electrochemical detection
of eugenol (EU) using polyacrylonitrile molecular imprinted polymer embedded
graphite (PAN-MIP/G) electrode. IEEE
Sensors Journal, 20(1), 39-46.
45. Chatterjee, T. N., Das, D., Roy, R.
B., Tudu, B., Sabhapondit, S., Tamuly, P., Pramanik, P., & Bandyopadhyay,
R. (2018). Molecular imprinted polymer based electrode for sensing catechin (+C)
in green tea. IEEE Sensors Journal, 18(6),
2236-2244.
46. Yang, S., Wang, Y., Xu, M., He, M.,
Zhang, M., Ran, D., & Jia, X. (2013). Synthesis of modified chitosan-based
molecularly imprinted polymers for adsorptive protein separation. Analytical Methods, 5(20), 5471-5477.
47. Khoo, W. C., Kamaruzaman, S., Lim,
H. N., Jamil, S. N. A. M., & Yahaya, N. (2019). Synthesis and
characterization of graphene oxide-molecularly imprinted polymer for Neopterin
adsorption study. Journal of Polymer
Research, 26(8), 184.
48. Saidin, M. I.,
Sidik, S. M., & Ul-Hamid, A. (2024). Nickel-Zinc supported on mesoporous
silica nanoparticles and its potential as a paracetamol sensor. Journal of
Smart Sensors and Materials, 2(1), 4.
49. Prabhu, S. N., Mukhopadhyay, S. C.,
Gooneratne, C. P., Davidson, A. S., & Liu, G. (2020). Molecularly imprinted
polymer-based detection of creatinine towards smart sensing. Medical Devices & Sensors, 3(6), e10133.
50. Prabhu, S. N., Gooneratne, C. P.,
& Mukhopadhyay, S. C. (2021). Development of MEMS sensor for detection of
creatinine using MIP based approach – a tutorial paper. IEEE Sensors Journal, 21(20),
22170-22181.
51. Mundinamani, S., & Rabinal, M.
K. (2014). Cyclic voltammetric studies on the role of electrode, electrode
surface modification and electrolyte solution of an electrochemical cell. IOSR Journal of Applied Chemistry, 7, 45-52.
52. Lin, R., Huang, P., Ségalini, J.,
Largeot, C., Taberna, P. L., Chmiola, J., Gogotsi, Y., & Simon, P. (2009).
Solvent effect on the ion adsorption from ionic liquid electrolyte into
sub-nanometer carbon pores. Electrochimica
Acta, 54(27), 7025-7032.
53. Said, N. A. M.,
Awaludin, N., Salam, F., Razali, H., Ghazali, M. S., Talib, M. A. A., ... &
Misman, S. N. (2023). Carboxylated multi-walled carbon nanotubes modified
screen-printed electrodes for early detection of rice diseases using
immunosensor approach. Journal of Smart Sensors and Materials, 1(1), 59-74.
54. Salinas-Torres, D., Huerta, F.,
Montilla, F., & Morallón, E. (2011). Study on electroactive and
electrocatalytic surfaces of single walled carbon nanotube-modified electrodes.
Electrochimica Acta, 56(5),
2464-2470.
55. Ahmad, K., Kumar, P., & Mobin,
S. M. (2020). A highly sensitive and selective hydroquinone sensor based on a
newly designed N-rGO/SrZrO3 composite. Nanoscale Advances, 2(1),
502-511.
56. Singh, R. K., & Schechter, A.
(2018). Electrochemical investigation of urea oxidation reaction on β
Ni(OH)2 and Ni/Ni(OH)2. Electrochimica Acta, 278, 405-411.
57. Sambasevam, K. P., Baharin, S. N.
A., Zulkifli, A., Raoov, M., Asman, S., Mohamed, A. H., & Marimuthu, T.
(2025). Factorial design assisted electrochemical detection of cypermethrin
using molecularly imprinted polyaniline. Pure
and Applied Chemistry, 97(8), 865-882.
58. Qiu, X., Xu, X.-Y., Liang, Y., &
Guo, H. (2018). The molecularly imprinted polymer supported by anodic alumina
oxide nanotubes membrane for efficient recognition of chloropropanols in
vegetable oils. Food Chemistry, 258,
295-300.
59. Banurea, I. R., Sanjaya, A. R.,
Nizardo, N. M., & Ivandini, T. A. (2023). Molecularly imprinted polymer of
p-amino thiophenol for a 3-monochloropropane-1,2-diol impedance-based sensor. Materials Chemistry and Physics, 301,
127613.
60. Han, S., Ding, Y., Teng, F., Yao,
A., & Leng, Q. (2021). Determination of chloropropanol with an imprinted
electrochemical sensor based on multi-walled carbon nanotubes/metal–organic
framework composites. RSC Advances, 11(30),
18468-18475.
61. Martin, A. A., Fodjo, E. K.,
Eric-Simon, Z. V., Gu, Z., Yang, G., Albert, T., Kong, C., & Wang, H.-F.
(2021). Cys-AgNPs modified gold electrode as an ultrasensitive electrochemical
sensor for the detection of 3-chloropropane-1, 2-diol. Arabian Journal of Chemistry,
14(9), 103319.
62. Rodríguez, L. C., Campańa, A. G.,
Barrero, F. A., Linares, C. J., & Ceba, M. R. (1995). Validation of an
analytical instrumental method by standard addition methodology. Journal of AOAC International, 78(2),
471-476.
63. Sambasevam, K. P., Mohamad, S.,
& Phang, S-W. (2017). Chemical sensor for hydrazine detection using
polyaniline thin film. Malaysian Journal of Analytical Sciences, 21(4),
762-769.
64. Saxberg, B. E., & Kowalski, B.
R. (1979). Generalized standard addition method. Analytical Chemistry, 51(7),
1031-1038.